Test Lab

We've specific definition on quality standards of our LED Work Lights, LED Driving Lights, and LED Headlights etc, and in order to fullfill these quality requirements, we'll arrange comprehensive tests for mechanical, electronic, and optical performance, include optical parameter test, vibration test, EMC test, salt spray test, high & low temperature test, waterproof test, aging test, beam pattern test, and beam angel test etc. All products could be released on the condition that pass all these essential test.

mflamps EMI Test

EMI Test

mflamps EMS Test

EMS Test

mflamps Integrating Sphere

Integrating Sphere

mflamps Goniophotometer

Goniophotometer

mflamps TEMPERATURE Test

TEMPERATURE Test

mflamps IPX9 TEST

IPX9 Test

mflamps Vibration Test

Vibration Test

mflamps CISPR 25 CLASS

CISPR 25 CLASS

IP6X,IPX8,IPX9K

ISO 20653-2013: Road vehicles - Degress of protection (IP Code) - Protection of electrical equipment against foreign objects, water and access

mflamps IP6X _ IPX8 _ IPX9K test 1
mflamps IP6X _ IPX8 _ IPX9K test 2
mflamps IP6X _ IPX8 _ IPX9K test 3
mflamps IP6X _ IPX8 _ IPX9K test 4

Test Requirement

IP6X test (Protection against access to hazardous parts):

The probe with a diameter of 1.0 mm does not enter the specimen case.

IP6X test (Protection against solid foreign objects):

Dust shall not penetrate.

IPX8 test (Continuous immersions subject to agreement):

Water shall not penetrate in a quantity causing harmful effects if the enclosure is continuously immersed in water under conditions which shall be agreed between supplier and car manufacturer, but which are more severe than code 7.

IPX9K test (Execution of the tests for protection against ingress of water):

No harmful effects or impair performance, no water enters the inside of the sample.

Mechanical shock test

ISO 16750-3:2012 4.2.2 and customer requirements

mflamps Mechanical shock test 1
mflamps Mechanical shock test 2
mflamps Mechanical shock test 3
mflamps Mechanical shock test 4

Test Procedure

Perform the test in accordance with IEC 60068-2-29 using the following test parameters:

  • operating mode of the DUT: 3.2 (see ISO 16750-1);
  • Pulse shape, Half-sinusoidal;
  • Acceleration: 500 m/s²;
  • Duration: 6ms;
  • Number of shocks: 10 per test direction;

Acceleration due to the shock in the test shall be applied in the same direction that acceleration of the shock occurs in the vehicle. If the direction of the effect is not known, the DUT shall be tested in all six spatial directions.

Requirements

Functional status shall be class A as defined in ISO 16750-1.

BEAM TEST

Each light pattern is designed and tested by optical engineers to give you the best possible beam pattern and comply with local legal requirements for on-road use

mflamps BEAM TEST 1
mflamps BEAM TEST 2
mflamps BEAM TEST 3
mflamps BEAM TEST 4

LOW BEAM SIMULATION

mflamps BEAM TEST 5

HIGH-LOW BEAM SIMULATON

CISPR CLASS TEST

mflamps CISPR CLASS TEST 1
mflamps CISPR CLASS TEST 2
mflamps CISPR CLASS TEST 3
mflamps CISPR CLASS TEST 4
mflamps CISPR CLASS TEST 5 mflamps CISPR CLASS TEST 6
Test Item Standard Class /Severity Test Setup and Procedure Result
Radiated Electromagnetic Interference_Voltage method (CISPR 25) CISPR 25:2016 Test frequency:
0.15MHz-2500MHz
Function status: meet the limit of Class 4
1) Set the EUT in accordance with the standard CISPR 25:2016, to connect the power verification sample function

2) The background noise is scanned, and confirmed to be at least 6dB below the limit.
Turn on the power supply and start the test. The positive and negative poles of the sample are measured by the L.I.S.N. When one port is measured in the artificial power network, the other port is connected to 50ohm matching load.

Pass
Conducted electromagnetic Interference_ALSE method (CISPR 25) CISPR 25:2016 Test frequency:
0.15MHz-108MHz
Function status: meet the limit of Class 4
1) Set the EUT accordance with the standard  CISPR 25:2016, to connect the power verification sample function

2) The background noise is scanned, and confirmed to be at least 6dB below the limit.

3) Turn on the power supply and start the test. The test frequency is less than 30MHz, with a single antenna, vertical polarization direction, the test frequency is greater than or equal to 30MHz, test the horizontal and vertical polarization direction respectively with double cone antenna, log periodic antenna and horn antenna.

In the test  frequency is less than 1000MHz, the antenna is measured sample harness center distance 1m, test frequency is greater than or equal to 1000MHz, the antenna is measured sample distance, 1m wire harness.

Pass

SALT SPRAY TEST

ISO 16750 4:2010 552 and custorner requirements

mflamps Salt Spray Test 1 mflamps Salt Spray Test 2
mflamps Salt Spray Test 3